BlitzFire®­­ Ground Monitor

Blitzfire.00 00 12 20.Still008 Copy

BlitzFire® Ground Monitor

BlitzFire®­­ Ground Monitor

Jump To…

KEY FEATURES | FAQ | SHOP BLITZFIRE

What is the BlitzFire?

The BlitzFire is a versatile, portable monitor that enables your crew to flow up to 500 GPM (2000 LPM) either in an attended or unattended mode. With the BlitzFire, a single firefighter can initiate an effective attack at almost any angle using just one hose line. Its exclusive safety shutoff valve ensures the protection of your crew, while its flexible range of attack angles provides various strategic options on the fire ground.

What Problems Does the BlitzFire Solve?

  • Limited Firefighting Personnel: When staffing is low, the BlitzFire allows a single firefighter to initiate an effective attack with just one hose line. The BlitzFire can also operate unassisted.
  • Risk of Uncontrolled Monitors: In unstable conditions, a BlitzFire’s built-in safety shutoff valve automatically activates, preventing uncontrolled movement and minimizing the risk of injury and equipment damage.
  • Challenges in Achieving Optimal Attack Angles: Firefighters often need to adjust their attack angles depending on the situation. The BlitzFire offers flexibility with adjustable angles ranging from 10 to 46 degrees, and up to 86 degrees in high elevation models, providing the necessary versatility for various fire ground strategies.
  • Limited Control Over Water Flow: Precise control over water delivery is crucial in many scenarios. A BlitzFire addresses this with its integrated slide valve, offering six detent positions to ensure complete control over the water stream.
  • Limited Storage Space on Apparatus: The BlitzFire can be mounted or stored easily in a compartment or preconnected to a hoseline.
  • Foam Application: Some monitors are not designed to handle foam effectively, limiting their usefulness. The BlitzFire is compatible with various foam systems, making it adaptable to different firefighting scenarios that require foam for effective suppression.
Blitzfire Copy

Looking at Portable Monitors?

New Copy
  • Portable Monitor Comparison Chart
  • Why a Portable Monitor? Key Benefits
  • Explore All Use Cases

Key Features of the BlitzFire Ground Monitor

Standard Model Stream Range

The adjustable attack angle of a standard BlitzFire unit ranges from 10 to 46 degrees, providing flexibility for a wide range of firefighting scenarios. Whether you’re attacking a fire from a low angle or need to reach higher areas, this feature ensures that the monitor can be positioned for maximum effectiveness.

High Elevation Model Stream Range

The high elevation model extends the vertical attack range from 10 to 86 degrees, ideal for fires requiring steep angles.

Flow Rate

The BlitzFire’s high flow rate allows for powerful water delivery, which is essential for quickly knocking down fires. The ability to flow up to 500 GPM (2000 LPM) ensures that firefighters can tackle even the most demanding fire scenarios with confidence, whether in an initial attack or for exposure protection.

Operate Unassisted

The BlitzFire can operate without direct human intervention, allowing firefighters to focus on other critical tasks. This capability is especially valuable in situations where staffing is limited, as it enables effective firefighting with fewer personnel on hand. A safety tiedown strap comes with the BlitzFire that meets the minimum NFPA safety guidelines.

Available Nozzle Pairings

The BlitzFire can be paired with a variety of nozzles, including standard, low-pressure, dual-pressure automatic, fixed gallonage, stacked tips, and foam tubes. This flexibility allows firefighters to tailor their equipment to the specific needs of the incident, ensuring the most effective water or foam delivery for the task at hand.

Optional Oscillation for Cooling and Protection

The optional oscillation feature uses a water-driven turbine to automatically sweep the nozzle across a range of 20, 30, or 40 degrees, providing consistent coverage without manual adjustment. This feature is particularly useful for cooling large areas or creating a protective barrier, enhancing the overall capability of the monitor.

Mounting and Storage

The BlitzFire can be easily mounted to any accessible vertical or horizontal surface on a fire apparatus or stored in a compartment for quick access. This convenient mounting and storage option ensures that the monitor is always ready for rapid deployment, saving valuable time during emergency operations.

Safety Shutoff Valve

With its integrated slide valve, the BlitzFire provides complete control over water flow, allowing firefighters to adjust the stream to meet the specific needs of the situation. The slide valve offers six distinct detent positions, providing precise control over the water flow. This versatility enables firefighters to quickly adapt to changing conditions, making it easier to manage both large-scale fires and more targeted attacks.

Foam Compatibility

The BlitzFire can be integrated with various foam systems, including eductors and on-board foam systems. This compatibility allows firefighters to deliver foam effectively, enhancing fire suppression capabilities, especially in situations where foam is required for greater knockdown power and to prevent re-ignition.

Complete Flow Control

With its integrated slide valve, the BlitzFire provides complete control over water flow, allowing firefighters to adjust the stream to meet the specific needs of the situation. The slide valve offers six distinct detent positions, providing precise control over the water flow. This versatility enables firefighters to quickly adapt to changing conditions, making it easier to manage both large-scale fires and more targeted attacks.

Carbide-Tipped Legs

The heavy-duty, carbide-tipped legs provide enhanced stability on a variety of surfaces, ensuring that the monitor remains securely in place during operation. This feature is particularly beneficial when deploying on uneven or slippery terrain, where maintaining a stable position is crucial for effective firefighting.

Rugged Aluminum Valve Handle

The rugged aluminum valve handle on the BlitzFire monitor offers dual functionality, serving both as a control mechanism and a built-in carrying handle. This design provides the benefit of enhanced portability, allowing firefighters to easily transport the monitor to the desired location with one hand, even in challenging environments.

Safety Locking Pin

The safety locking pin secures the monitor’s off position to prevent unintentional flow of water.

Frequently Asked Questions About the BlitzFire (FAQ)

The BlitzFire monitor is designed for single-person operation, allowing one firefighter to effectively manage water flow and attack angles. Its portability and unattended operation capability make it ideal for departments with limited personnel, ensuring effective firefighting without requiring a large team.

Yes, the BlitzFire monitor is compatible with various foam systems, including eductors and onboard foam setups. This versatility allows firefighters to quickly switch between water and foam, depending on the suppression needs, making it suitable for multiple fire scenarios, including Class A and B fires.

The BlitzFire monitor features an exclusive safety shutoff valve that automatically engages if the monitor experiences unintentional movement. This is crucial in preventing injury or equipment damage, particularly when the monitor is being used in high-pressure or unstable conditions.

One of the key advantages of the BlitzFire is its compact size, which allows it to be stored easily in most apparatus compartments or mounted on vertical or horizontal surfaces. This ensures that it doesn’t take up valuable space while remaining readily accessible for quick deployment during emergencies.

Yes, the high-elevation version of the BlitzFire monitor extends the vertical attack range up to 86 degrees, making it an ideal solution for targeting elevated locations such as attic fires or fires in multi-story buildings. This capability provides tactical flexibility in a wide variety of fire situations.

Yes, the BlitzFire monitor comes with a safety tiedown strap that meets the minimum NFPA safety guidelines. This ensures that the monitor is securely anchored during use, providing added safety for firefighters in high-pressure or dynamic fireground environments.

Jump To TOP OF PAGE

Demos.00 00 14 10.Still001 Copy

Ready to Get Hands-On?

Screenshot 2024 10 31 113430
  • Custom, Hands-On Demonstrations
  • Comprehensive Product Insights
  • Tactical Guidance Tailored to Your Needs
  • Personalized Equipment Recommendations
  • Immediate Answers to All Your Questions
  • Exclusive, 1-on-1 Expert Support
  • Flexible Scheduling to Suit Your Availability