Yes, and it is very common that a department’s initial attack package has a certain size smooth bore and a fog nozzle to hydraulically match that smoothbore.
Check the pressure and flow rating of your current smooth bore and make sure that pressure and flow rating match the Metro nozzle option you are trying to specify.
For example, a 7/8” smooth bore which delivers 160 GPM @ 50 PSI, the Metro nozzle model specified should also be 160 GPM @ 50 PSI, which would be TFT model number ME1V-226.