Loading monitor explorer…

Portable ground monitor specifications and sources

Compare vertical elevation and operator requirements for portable firefighting monitors. Unattended elevation means the outlet can hold the stated angle without an operator holding it; approved anchoring and all manufacturer operating requirements still apply.

Elevation ranges by model and configuration
MonitorTotal vertical elevationUnattended elevation rangeSafety flow response
Task Force Tips BlitzFire — Standard · non-oscillating10–46°10–46°Safety shutoff included
Task Force Tips BlitzFire HE — High elevation · non-oscillating10–86°10–86°Safety shutoff included
Akron Brass Mercury Quick Attack LE — Style 3444 · standard configuration10–50°30–50°Not included in standard configuration
Elkhart Brass RAM XD — Model 829614–51°35–51°No movement-triggered shutoff documented
Task Force Tips BlitzForce — XXL111A · non-oscillating20–60°30–60°No movement-triggered shutoff documented
Conditions and manufacturer documentation

BlitzFire — Standard · non-oscillating: Securing the monitor, ground contact and the manual’s pressure/flow envelope remain required. Manual override requires an operator. BlitzFire manual · Rev 24 · §§4.2, 4.5–4.6

BlitzFire HE — High elevation · non-oscillating: Securing the monitor, ground contact and the manual’s pressure/flow envelope remain required. Manual override requires an operator. BlitzFire manual · Rev 24 · §§4.2, 4.5–4.6

Mercury Quick Attack LE — Style 3444 · standard configuration: A secured safety strap and the manual’s setup, pressure and nozzle limits still apply. Style 3444 manual · Rotation and Elevation

RAM XD — Model 8296: A secured strap and full ground contact remain required. The valve-handle lock prevents unintended opening; it is distinct from the self-elevating system. 8296 RAM XD manual · pp. 5, 7, 10

BlitzForce — XXL111A · non-oscillating: Always tie off the monitor and maintain all three spikes in contact with the ground. Follow the manual’s operating envelope and nozzle weight/length limits. Below 30°, an operator must hold the outlet. BlitzForce manual · Rev 14 · §§3.2, 3.6, 3.9–3.10, 6

Scenes and angle guides illustrate elevation only. They do not predict stream reach, fire suppression effectiveness or a safe operating position. Follow the manufacturer manual.