Changing the Ball Seat and Clapper Seal on an Oasis Valve

The process for replacing the ball seat and clapper seal on your Oasis Hydrant Assist Valve is easy!   Tools Needed:   1/8” Allen Wrench  3/32” Allen Wrench  5/32” Allen Wrench  Pointed seal pick  1.25” Combination Wrench or Crescent Wrench  Light Grease  Changing the Ball Seat:  Using your 1/8” allen wrench, back out the set […]

Using Water Flow Meters and Pressure Gauges During Nozzle Evaluation

Are you evaluating new firefighting nozzles for your crew? Are you completing NFPA (National Fire Protection Association) tests on your nozzles?   When you do either of these activities, you know that having the best, most accurate information is necessary. You’ve probably heard someone mention the use of a pressure gauge and water flow meter for […]

How Does Water Supply Affect Your Firefighting Nozzle Choice?

Getting water to the fire in the fastest way possible is arguably one of the most important tactics on the fire ground aside from preservation of life. That’s why the fire service is so passionate about their nozzle selection. Your nozzle is the first line of defense in saving lives and protecting property for the majority […]

5 Intake Valve Considerations for Industrial Facilities and Refineries

Industrial facilities and refineries have a unique set of needs when it comes to water flow. For you, fire suppression means using a high volume of water to mitigate damage and minimize loss. The intake valves you use need to be reliable and ready to be an intake or discharge as they’re used on apparatus, […]