|
XFI-FLNJ |
HURRICANE MONITOR The most rugged, most advanced design for an industrial monitor ever. The large 3.25" (83mm) waterway will deliver up to 1250 gpm (4500 l/min). Only eleven (11) turns of the handwheel are necessary to change from vertical to the horizontal elevation setting. A built-in automatic drain protects the monitor from freezing. 2.5" male NH (65mm) outlet threads are standard. 2.5" male BSP (65mm) threads available on request. NOTE: The riser must be supported to safely withstand a nozzle reaction force of up to 900 lbs (408kg). (1250 gpm at 175 psi)(4500 l/min @ 12 bar).
|
|
XFI-FPNJ |
HURRICANE MONITOR The most rugged, most advanced design for an industrial monitor ever. The large 3.25" (83mm) waterway will deliver up to 1250 gpm (4500 l/min). Only eleven (11) turns of the handwheel are necessary to change from vertical to the horizontal elevation setting. A built-in automatic drain protects the monitor from freezing. 2.5" male NH (65mm) outlet threads are standard. 2.5" male BSP (65mm) threads available on request. NOTE: The riser must be supported to safely withstand a nozzle reaction force of up to 900 lbs (408kg). (1250 gpm at 175 psi)(4500 l/min @ 12 bar).
|
|
XFI-OXY |
HURRICANE MONITOR ALUMINUM
|
|
XFI-PLNJ |
HURRICANE MONITOR The most rugged, most advanced design for an industrial monitor ever. The large 3.25" (83mm) waterway will deliver up to 1250 gpm (4500 l/min). Only eleven (11) turns of the handwheel are necessary to change from vertical to the horizontal elevation setting. A built-in automatic drain protects the monitor from freezing. 2.5" male NH (65mm) outlet threads are standard. 2.5" male BSP (65mm) threads available on request. NOTE: The riser must be supported to safely withstand a nozzle reaction force of up to 900 lbs (408kg). (1250 gpm at 175 psi)(4500 l/min @ 12 bar).
|
|
XFIE-FLNJ |
HURRICANE MONITOR The most rugged, most advanced design for an industrial monitor ever. The large 3.25" (83mm) waterway will deliver up to 1250 gpm (4500 l/min). Only eleven (11) turns of the handwheel are necessary to change from vertical to the horizontal elevation setting. A built-in automatic drain protects the monitor from freezing. 2.5" male NH (65mm) outlet threads are standard. 2.5" male BSP (65mm) threads available on request. NOTE: The riser must be supported to safely withstand a nozzle reaction force of up to 900 lbs (408kg). (1250 gpm at 175 psi)(4500 l/min @ 12 bar).
|
|
|
XFIF-PLNJ |
HURRICANE MONITOR ALUMINUM
|
|
|
XFIH-DL1A |
HURRICANE DUAL HNDWHL CODE-RPF 3" INLET
|
|
|
XFIH-DP1A |
HURRICANE DUAL HNDWHL CODE-RPF 4" INLET
|
|
|
XFIH-DQ1A |
HURRICANE DUAL HWHL 4.5"NHF QUICKCONNECT
|
|
|
XFIH-DR1A |
HURRICANE DUAL HWHL 4.5"QC 4"ANSI INLET
|
|
|
XFIH-DS1A |
HURRICANE DUAL HWHL 4.5"QC 4"NPTF INLET
|
|
|
XFIH-DT1A |
HURRICANE DUAL HWHL 4.5"QC CODE-RLF INLT
|
|
|
XFIH-DU1A |
HURRICANE DUAL HWHL 4.5"QC CODE-RPF INLT
|
|
|
XFIH-DX1A |
HURRICANE DUAL HWHL CODE-RRM INLET
|
|
|
XFIH-TP1A |
HURRICANE TILLER CODE-RPF 4" INLET
|
|
|
|
|
XFIH-TQ1A |
HURRICANE TILLER 4.5"NHF QUICK CONNECT
|
|
|
XFIH-TR1A |
HURRICANE TILLER 4.5"QC 4"ANSI INLET
|
|
|
XFIH-TS1A |
HURRICANE TILLER 4.5"QC 4"NPTF INLET
|
|
|
XFIH-TT1A |
RICANE TILLER 4.5"QC CODE-RLF INLET
|
|
|
XFIH-TU1A |
HURRICANE TILLER 4.5"QC CODE-RPF INLET
|
|
|
XFIH-TX1A |
HURRICANE TILLER CODE-RRM INLET
|
|
|
Y5-TR1A |
TYPHOON TILLER 4.5"QC 4"ANSI INLET
|
|
|